Microsoft MVP성태의 닷넷 이야기
글쓴 사람
정성태 (techsharer at outlook.com)
홈페이지
첨부 파일
(연관된 글이 1개 있습니다.)
(시리즈 글이 12개 있습니다.)
.NET Framework: 811. (번역글) .NET Internals Cookbook Part 1 - Exceptions, filters and corrupted processes
; https://www.sysnet.pe.kr/2/0/11838

.NET Framework: 816. (번역글) .NET Internals Cookbook Part 2 - GC-related things
; https://www.sysnet.pe.kr/2/0/11869

.NET Framework: 818. (번역글) .NET Internals Cookbook Part 3 - Initialization tricks
; https://www.sysnet.pe.kr/2/0/11871

.NET Framework: 819. (번역글) .NET Internals Cookbook Part 4 - Type members
; https://www.sysnet.pe.kr/2/0/11872

.NET Framework: 820. (번역글) .NET Internals Cookbook Part 5 - Methods, parameters, modifiers
; https://www.sysnet.pe.kr/2/0/11873

.NET Framework: 821. (번역글) .NET Internals Cookbook Part 6 - Object internals
; https://www.sysnet.pe.kr/2/0/11874

.NET Framework: 822. (번역글) .NET Internals Cookbook Part 7 - Word tearing, locking and others
; https://www.sysnet.pe.kr/2/0/11876

.NET Framework: 823. (번역글) .NET Internals Cookbook Part 8 - C# gotchas
; https://www.sysnet.pe.kr/2/0/11877

.NET Framework: 824. (번역글) .NET Internals Cookbook Part 9 - Finalizers, queues, card tables and other GC stuff
; https://www.sysnet.pe.kr/2/0/11878

.NET Framework: 825. (번역글) .NET Internals Cookbook Part 10 - Threads, Tasks, asynchronous code and others
; https://www.sysnet.pe.kr/2/0/11879

.NET Framework: 826. (번역글) .NET Internals Cookbook Part 11 - Various C# riddles
; https://www.sysnet.pe.kr/2/0/11882

.NET Framework: 831. (번역글) .NET Internals Cookbook Part 12 - Memory structure, attributes, handles
; https://www.sysnet.pe.kr/2/0/11891




(번역글) .NET Internals Cookbook Part 7 - Word tearing, locking and others


이번에도 .NET Internals Cookbook 시리즈의 7번째 글을 번역한 것입니다.

.NET Internals Cookbook Part 7 - Word tearing, locking and others
; https://blog.adamfurmanek.pl/2019/03/30/net-internals-cookbook-part-7/





45. 그래도 박싱(boxing)이 필요한 경우?

박싱은 스택의 데이터를 힙에 중복해서 올리기 때문에 분명히 성능상 좋은 작업은 아닙니다. 하지만, 필드를 많이 가진 값 형식의 인스턴스를 다룰 때 값의 치환을 스레드에 안정적으로 다루는 용도로 사용할 수 있습니다.

가령 다음과 같은 struct를,

struct Foo
{
    public int A { get; set; }
    public int B { get; set; }
    public int C { get; set; }
    public int D { get; set; }
    public int E { get; set; }
}

보유한 클래스가 있다고 가정해 보겠습니다.

public class Test
{
    Foo _foo = new Foo();

    public void ChangeFoo(Foo foo)
    {
        _foo = foo;
    }

    public void WriteValues()
    {
        Console.WriteLine(_foo.A);
        Console.WriteLine(_foo.E);
    }
}

위에서 _foo = foo 대입문은 5개의 int 필드에 대한 값 복사가 발생합니다. 즉, 코드는 한 줄이지만 실제로는 다음과 같은 코드가 실행되는 것과 같습니다.

_foo.A = foo.A;
_foo.B = foo.B;
_foo.C = foo.C;
_foo.D = foo.D;
_foo.E = foo.E;

일반적인 경우 저런 코드가 문제 되지 않지만 만약 다중 스레드 상황으로 바뀌면 의도치 않은 버그가 발생할 수 있습니다. 가령 A 스레드가 foo 구조체의 A, B까지 값을 대입한 상황에서 B 스레드가 WriteValues 메서드를 호출해 A와 E 멤버를 접근하면 foo가 _foo에 완전하게 대입되기도 전에 값을 접근하는 결과가 됩니다.

저런 경우를 방지하기 위해서는 Foo를 class로 바꾸고 다음과 같은 식으로 코딩하면 됩니다.

public class Test
{
    Foo _foo = new Foo();

    public void ChangeFoo(Foo foo)
    {
        _foo = foo;
    }

    public void WriteValues()
    {
        Foo temp = _foo;

        Console.WriteLine(temp.A);
        Console.WriteLine(temp.E);
    }
}

참조 형식의 경우 GC Heap을 가리키는 주솟값(x86 4바이트, x64 8바이트)에 불과하기 때문에 대입 과정이 atomic하게 처리되기 때문입니다.

또는, class로 바꾸지 않고 의도적으로 필요한 순간에만 박싱을 해 주솟값 대입으로 변경하는 방법도 있습니다.

public class Test
{
    object _foo = new Foo();

    public void ChangeFoo(Foo foo)
    {
        _foo = foo;
    }

    public void WriteValues()
    {
        object obj = _foo;
        Foo temp = (Foo)obj;

        Console.WriteLine(temp.A);
        Console.WriteLine(temp.E);
    }
}

위와 같은 특징을 감안하고 원 글(.NET Internals Cookbook Part 7 ? Word tearing, locking and others)의 예제 코드를 보면,

using System;
using System.Collections.Generic;
using System.Linq;
using System.Threading;
using System.Threading.Tasks;

public class Program
{
    public static void Main()
    {
        var source = Enumerable.Range(0, 1000).ToArray();
        while(true)
        {
            Foo result = UnsafeParallel(source, n => {
                Thread.Sleep(0);
                return new Foo { A = n, B = n, C = n, D = n, E = n };
            });

            if (result.A != result.B || result.A != result.C || result.A != result.D || result.A != result.E)
            {
                Console.WriteLine("Tearing detected!");
                Console.WriteLine(result.A);
                Console.WriteLine(result.B);
                Console.WriteLine(result.C);
                Console.WriteLine(result.D);
                Console.WriteLine(result.E);
                break;
            }
        }
    }

    static T UnsafeParallel(IEnumerable source, Func action)
    {
        T result = default(T);
        Parallel.ForEach(source, (i, state) => {
            result = action(i);
            state.Stop();
        });

        return result;
    }


    static T SafeParallel(IEnumerable source, Func action)
    {
        object result = default(T);
        Parallel.ForEach(source, (i, state) => {
            result = action(i);
            state.Stop();
        });

        return (T)result;
    }
}

왜 UnsafeParallel에서는 문제가 발생하고, SafeParallel에서는 문제가 발생하지 않는지 이해할 수 있을 것입니다.





46. 다중 연결된 delegate의 경우 중간 호출에서 예외가 발생한다면?

예를 들어 다음의 코드를 보면,

using System;

public class Program
{
    delegate void Foo();
    public static void Main()
    {
        Foo foo = () => Console.WriteLine("First");
        foo += () => throw new Exception("Second");
        foo += () => Console.WriteLine("Third");

        try
        {
            foo();
        }
        catch (Exception e)
        {
            Console.WriteLine(e);
        }
    }
}

/* 출력 결과
First
System.Exception: Second
   at Program.<>c.<Main>b__1_1() in C:\temp\cookbook_series7_sample\q46\ConsoleApp1\Program.cs:line 9
   at Program.Foo.Invoke()
   at Program.Main() in C:\temp\cookbook_series7_sample\q46\ConsoleApp1\Program.cs:line 14
*/

두 번째 연결된 delegate 호출에서 예외가 발생하므로 그 이후의 콜백 호출이 안 되는 것을 볼 수 있습니다. 만약 예외를 감안해 모든 delegate를 호출하고 싶다면 다음의 글에서 설명한,

올바른 이벤트 예외 정보 출력
; https://www.sysnet.pe.kr/2/0/620

GetInvocationList 메서드를 이용해 하나씩 try/catch로 감쌀 수 있습니다.





47. foreach 문을 사용하려면 IEnumerator/IEnumerable 인터페이스를 반드시 구현해야 할까?

다음의 코드에서 보듯이,

using System;

public class Program
{
    public static void Main()
    {
        var bar = new Bar();

        foreach (int item in bar)
        {
            Console.WriteLine(item);
        }
    }
}

class Foo
{
    public int Current { get; private set; }
    private int step;
    public bool MoveNext()
    {
        if (step >= 5) return false;
        Current = step++;
        return true;
    }
}

class Bar
{
    public Foo GetEnumerator() { return new Foo(); }
}

IEnumerator/IEnumerable 인터페이스를 굳이 명시하지 않아도 관련 속성과 메서드를 가지는 것만으로 C# 컴파일러는 foreach에 해당 멤버들을 사용해 코드를 생성해 줍니다.

이 규칙은 비동기 호출에 관련된 await에도 적용되는데 다음의 코드를 보면 정숫값(2000)을 await할 수 있도록 확장 메서드를 연결하고 있습니다.

using System;
using System.Runtime.CompilerServices;
using System.Threading.Tasks;

namespace AwaitOnInteger
{
    class Program
    {
        static void Main(string[] args)
        {
            WaitForInt().Wait();
        }

        static async Task WaitForInt()
        {
            Console.WriteLine($"Waiting starting at {DateTime.Now}");
            await 2000;
            Console.WriteLine($"Waiting finished at {DateTime.Now}");

        }
    }

    public static class AwaitableInt
    {
        public static TaskAwaiter GetAwaiter(this int miliseconds)
        {
            return Task.Delay(TimeSpan.FromMilliseconds(miliseconds)).GetAwaiter();
        }
    }
}

위의 규칙에 대해서는 저도 예전에 ^^ 설명한 적이 있습니다.

C# - await을 Task 타입이 아닌 사용자 정의 타입에 적용하는 방법
; https://www.sysnet.pe.kr/2/0/11456





48. LINQ 쿼리의 동작과 컴파일 방식

SQL 쿼리 구문처럼 보이는 LINQ는,

using System;
using System.Linq;

namespace Program
{
    public class Program
    {
        public static void Main(string[] args)
        {
            var source = Enumerable.Range(0, 100);
            var filtered = from i in source 
                           where i % 3 == 0 
                           select i / 2;
        }
    }
}

빌드하면 결국 관련된 IEnumerable의 확장 메서드로 번역이 된다는 것을 .NET Reflector 도구 등으로 확인해 보면 알 수 있습니다.

using System;
using System.Collections.Generic;
using System.Linq;
using System.Runtime.CompilerServices;
namespace Program
{
    public class Program
    {
        [CompilerGenerated]
        [Serializable]
        private sealed class <>c
        {
            public static readonly Program.<>c <>9 = new Program.<>c();
            public static Func <>9__0_0;
            public static Func <>9__0_1;
            internal bool b__0_0(int i)
            {
                return i % 3 == 0;
            }
            internal int b__0_1(int i)
            {
                return i / 2;
            }
        }
        public static void Main(string[] args)
        {
            IEnumerable enumerable = Enumerable.Range(0, 100);
            IEnumerable arg_2A_0 = enumerable;
            Func arg_2A_1;
            if ((arg_2A_1 = Program.<>c.<>9__0_0) == null)
            {
                arg_2A_1 = (Program.<>c.<>9__0_0 = new Func(Program.<>c.<>9.b__0_0));
            }
            IEnumerable arg_4E_0 = arg_2A_0.Where(arg_2A_1);
            Func arg_4E_1;
            if ((arg_4E_1 = Program.<>c.<>9__0_1) == null)
            {
                arg_4E_1 = (Program.<>c.<>9__0_1 = new Func(Program.<>c.<>9.b__0_1));
            }
            IEnumerable enumerable2 = arg_4E_0.Select(arg_4E_1);
        }
    }
}





49. IEnumerable.Select와 IQueryable.Select의 차이점

메서드 시그니처를 보면,

[IEnumerable.Select]
public static System.Collections.Generic.IEnumerable Select (this System.Collections.Generic.IEnumerable source, Func selector);

[IQueryable.Select]
public static System.Linq.IQueryable Select (this System.Linq.IQueryable source, System.Linq.Expressions.Expression> selector);

IEnumerable 측은 람다를 코드(Func)로 받아들여 실행시키는 반면 IQueryable의 경우 람다를 데이터(System.Linq.Expressions.Expression)로 받아들여 분석해 실행 시 SQL 쿼리로 번역합니다.





50. Reflection으로 private 멤버를 접근하지 못하도록 막는 방법

.NET 4.6/.NET Core 1.0부터 제공되는 DisablePrivateReflectionAttribute 특성을 어셈블리 수준에 부여하거나,

[assembly: DisablePrivateReflection]

ReflectionPermission을 사용하면 된다고 합니다.

그런데, 실제로 해보면 .NET Framework 응용 프로그램에서는 동작하지 않고, .NET Core에서만 동작합니다. 예를 들어 다음의 코드를 .NET Standard 라이브러리로 만들고,

using System;
using System.Runtime.CompilerServices;

[assembly: DisablePrivateReflection]

public class Class1
{
    private int i = 5;

    public void Print()
    {
        Console.WriteLine(i);
    }
}

.NET Core 콘솔에서 다음과 같이 Class1을 사용하면,

using System;
using System.Reflection;

class Program
{
    static void Main(string[] args)
    {
        Class1 cl = new Class1();
        cl.Print();

        SetPrivate(cl, 6);
        cl.Print();
    }

    private static void SetPrivate(Class1 cl, int v)
    {
        Type type = cl.GetType();

        FieldInfo fi = type.GetField("i", System.Reflection.BindingFlags.NonPublic | System.Reflection.BindingFlags.Instance);
        if (fi == null)
        {
            return;
        }

        fi.SetValue(cl, v);
    }
}

SetValue 메서드 수행에서 다음과 같은 예외가 발생합니다.

Unhandled Exception: System.FieldAccessException: Attempt by method 'Program.SetPrivate(Class1, Int32)' to access field 'Class1.i' failed.
   at System.Reflection.RtFieldInfo.PerformVisibilityCheckOnField(IntPtr field, Object target, RuntimeType declaringType, FieldAttributes attr, UInt32 invocationFlags)
   at System.Reflection.RtFieldInfo.InternalSetValue(Object obj, Object value, BindingFlags invokeAttr, Binder binder, CultureInfo culture, StackCrawlMark& stackMark)
   at System.Reflection.RtFieldInfo.SetValue(Object obj, Object value, BindingFlags invokeAttr, Binder binder, CultureInfo culture)
   at System.Reflection.FieldInfo.SetValue(Object obj, Object value)
   at Program.SetPrivate(Class1 cl, Int32 v) in C:\temp\NetCoreCon1\Program.cs:line 25
   at Program.Main(String[] args) in C:\temp\NetCoreCon1\Program.cs:line 11

반면 동일한 코드를 .NET Framework 응용 프로그램에서 실행하면 예외가 발생하지 않습니다.





51. lock 구문에 값 형식(value type)의 인스턴스를 사용할 수 있을까?

아래의 글에서도 설명했지만,

.NET 참조 개체 인스턴스의 Object Header를 확인하는 방법
; https://www.sysnet.pe.kr/2/0/1175

값 형식은 Object Header가 없기 때문에 lock 구문으로 사용할 수 없습니다. 그래서 다음과 같이 lock에 사용하려고 시도하면 컴파일 오류가 발생합니다.

using System;

public class Program
{
    public static void Main(string[] args)
    {
        int i = 5;

        // 컴파일 에러
        // error CS0185: 'int' is not a reference type as required by the lock statement
        lock(i) {
        }
    }
}

lock 구문이 실제로는 Monitor.Enter 코드로 변경된다는 것을 지난 글에서 설명했는데요. 따라서 다음과 같이 풀어서 접근하는 것을 시도해 볼 수는 있습니다.

int i = 5;
bool wasTaken = false;
try
{
    Monitor.Enter(i, ref wasTaken);
}
finally
{
    if (wasTaken)
    {
        Monitor.Exit(i);
    }
}

이번엔 컴파일 오류는 발생하지 않지만, 실행 시 다음과 같은 오류가 발생합니다.

Unhandled Exception: System.Threading.SynchronizationLockException: Object synchronization method was called from an unsynchronized block of code.

왜냐하면, Monitor.Enter의 첫 번째 인자는 object 타입이므로 int i는 object로 박싱되어 컴파일을 통과할 수 있었지만, Monitor.Exit에 사용된 i도 그 순간 새롭게 object로 박싱된 것이므로 Enter와 Exit에 사용된 객체가 같지 않기 때문입니다. 결국 Exit(i)의 박싱된 object는 Enter에 사용된 적이 없으므로 Exit에서 해제 시 오류가 발생하는 것입니다.

(첨부 파일은 이 글의 예제 코드를 포함합니다.)



[이 글에 대해서 여러분들과 의견을 공유하고 싶습니다. 틀리거나 미흡한 부분 또는 의문 사항이 있으시면 언제든 댓글 남겨주십시오.]

[연관 글]






[최초 등록일: ]
[최종 수정일: 4/19/2024]

Creative Commons License
이 저작물은 크리에이티브 커먼즈 코리아 저작자표시-비영리-변경금지 2.0 대한민국 라이센스에 따라 이용하실 수 있습니다.
by SeongTae Jeong, mailto:techsharer at outlook.com

비밀번호

댓글 작성자
 




... 31  32  33  34  35  36  37  38  [39]  40  41  42  43  44  45  ...
NoWriterDateCnt.TitleFile(s)
12655정성태6/1/20217723오류 유형: 722. windbg/sos - savemodule - Fail to read memory
12654정성태5/31/20217744오류 유형: 721. Hyper-V - Saved 상태의 VM을 시작 시 오류 발생
12653정성태5/31/202110412.NET Framework: 1060. 닷넷 GC에 새롭게 구현되는 DPAD(Dynamic Promotion And Demotion for GC)
12652정성태5/31/20218517VS.NET IDE: 164. Visual Studio - Web Deploy로 Publish 시 암호창이 매번 뜨는 문제
12651정성태5/31/20218761오류 유형: 720. PostgreSQL - ERROR: 22P02: malformed array literal: "..."
12650정성태5/17/20218075기타: 82. OpenTabletDriver의 버튼에 더블 클릭을 매핑 및 게임에서의 지원 방법
12649정성태5/16/20219403.NET Framework: 1059. 세대 별 GC(Garbage Collection) 방식에서 Card table의 사용 의미 [1]
12648정성태5/16/20218039사물인터넷: 66. PC -> FTDI -> NodeMCU v1 ESP8266 기기를 UART 핀을 연결해 직렬 통신하는 방법파일 다운로드1
12647정성태5/15/20219305.NET Framework: 1058. C# - C++과의 연동을 위한 구조체의 fixed 배열 필드 사용파일 다운로드1
12646정성태5/15/20218418사물인터넷: 65. C# - Arduino IDE의 Serial Monitor 기능 구현파일 다운로드1
12645정성태5/14/20218126사물인터넷: 64. NodeMCU v1 ESP8266 - LittleFS를 이용한 와이파이 접속 정보 업데이트파일 다운로드1
12644정성태5/14/20219240오류 유형: 719. 윈도우 - 제어판의 "프로그램 및 기능" / "Windows 기능 켜기/끄기" 오류 0x800736B3
12643정성태5/14/20218439오류 유형: 718. 서버 유형의 COM+ 사용 시 0x80080005(Server execution failed) 오류 발생
12642정성태5/14/20219375오류 유형: 717. The 'Microsoft.ACE.OLEDB.12.0' provider is not registered on the local machine.
12641정성태5/13/20219061디버깅 기술: 179. 윈도우용 .NET Core 3 이상에서 Windbg의 sos 사용법
12640정성태5/13/202112020오류 유형: 716. RDP 연결 - Because of a protocol error (code: 0x112f), the remote session will be disconnected. [1]
12639정성태5/12/20218880오류 유형: 715. Arduino: Open Serial Monitor - The module '...\detection.node' was compiled against a different Node.js version using NODE_MODULE_VERSION
12638정성태5/12/20219835사물인터넷: 63. NodeMCU v1 ESP8266 - 펌웨어 내 파일 시스템(SPIFFS, LittleFS) 및 EEPROM 활용
12637정성태5/10/20219444사물인터넷: 62. NodeMCU v1 ESP8266 보드의 A0 핀에 다중 아날로그 센서 연결 [1]
12636정성태5/10/20219670사물인터넷: 61. NodeMCU v1 ESP8266 보드의 A0 핀 사용법 - FSR-402 아날로그 압력 센서 연동파일 다운로드1
12635정성태5/9/20218978기타: 81. OpenTabletDriver를 (관리자 권한으로 실행하지 않고도) 관리자 권한의 프로그램에서 동작하게 만드는 방법
12634정성태5/9/20218042개발 환경 구성: 572. .NET에서의 신뢰도 등급 조정 - 외부 Manifest 파일을 두는 방법파일 다운로드1
12633정성태5/7/20219528개발 환경 구성: 571. UAC - 관리자 권한 없이 UIPI 제약을 없애는 방법
12632정성태5/7/20219715기타: 80. (WACOM도 지원하는) Tablet 공통 디바이스 드라이버 - OpenTabletDriver
12631정성태5/5/20219610사물인터넷: 60. ThingSpeak 사물인터넷 플랫폼에 ESP8266 NodeMCU v1 + 조도 센서 장비 연동파일 다운로드1
12630정성태5/5/20219928사물인터넷: 59. NodeMCU v1 ESP8266 보드의 A0 핀 사용법 - CdS Cell(GL3526) 조도 센서 연동파일 다운로드1
... 31  32  33  34  35  36  37  38  [39]  40  41  42  43  44  45  ...