Windbg - ERROR: Unable to load DLL mscordacwks_x86_x86_2.0.50727.4200.dll, Win32 error 0n2

procdump.exe를 이용해서 생성한 닷넷 응용 프로그램의 덤프를 고객사로부터 전달받아 windbg에 올려서 분석을 시작하려고 했습니다.

windbg를 실행하고, 덤프를 로드하니 아래와 같이 procdump.exe를 이용하여 덤프를 받은 상황을 보여줍니다.

Loading Dump File [D:\...[생략]...\TestApp_110119_154225.dmp]
User Mini Dump File with Full Memory: Only application data is available

Comment: '
*** procdump  -e -ma -t TestApp.exe
*** Unhandled exception'
Symbol search path is: SRV*\\localhost\e$\Symbols*http://msdl.microsoft.com/download/symbols;
Executable search path is:
Windows Server 2008/Windows Vista Version 6002 (Service Pack 2) MP (8 procs) Free x86 compatible
Product: Server, suite: TerminalServer SingleUserTS
Machine Name:
Debug session time: Wed Jan 19 15:42:25.000 2011 (UTC + 9:00)
System Uptime: 5 days 19:17:25.877
Process Uptime: 0 days 0:00:53.000

여느 때와 다름없이 sos.dll을 로드하고,

0:000> .loadby sos mscorwks

예외 발생을 파악하기 위해 "!pe (printexception의 간략 명령어)" 명령을 내렸으나 다음과 같이 실행이 안되었습니다.

0:000> !pe
CLRDLL: CLR DLL load disabled
Failed to load data access DLL, 0x80004005
Verify that 1) you have a recent build of the debugger (6.2.14 or newer)
            2) the file mscordacwks.dll that matches your version of mscorwks.dll is 
                in the version directory
            3) or, if you are debugging a dump file, verify that the file 
                mscordacwks_<arch>_<arch>_<version>.dll is on your symbol path.
            4) you are debugging on the same architecture as the dump file.
                For example, an IA64 dump file must be debugged on an IA64
                machine.

You can also run the debugger command .cordll to control the debugger's
load of mscordacwks.dll.  .cordll -ve -u -l will do a verbose reload.
If that succeeds, the SOS command should work on retry.

If you are debugging a minidump, you need to make sure that your executable
path is pointing to mscorwks.dll as well.

혹시나 싶어 다른 명령도 수행해봤는데, 출력 결과만 좀 더 자세할 뿐 역시 오류가 발생합니다.

0:000> !clrstack
CLRDLL: C:\Windows\Microsoft.NET\Framework\v2.0.50727\mscordacwks.dll:2.0.50727.4952 f:0
doesn't match desired version 2.0.50727.4200 f:0
CLRDLL: Unable to find mscordacwks_x86_x86_2.0.50727.4200.dll by mscorwks search
CLRDLL: Unable to find 'mscordacwks_x86_x86_2.0.50727.4200.dll' on the path
CLRDLL: Unable to find mscorwks.dll by search
CLRDLL: ERROR: Unable to load DLL mscordacwks_x86_x86_2.0.50727.4200.dll, Win32 error 0n2
Failed to load data access DLL, 0x80004005
Verify that 1) you have a recent build of the debugger (6.2.14 or newer)
            2) the file mscordacwks.dll that matches your version of mscorwks.dll is 
                in the version directory
            3) or, if you are debugging a dump file, verify that the file 
                mscordacwks_<arch>_<arch>_<version>.dll is on your symbol path.
            4) you are debugging on the same architecture as the dump file.
                For example, an IA64 dump file must be debugged on an IA64
                machine.

You can also run the debugger command .cordll to control the debugger's
load of mscordacwks.dll.  .cordll -ve -u -l will do a verbose reload.
If that succeeds, the SOS command should work on retry.

If you are debugging a minidump, you need to make sure that your executable
path is pointing to mscorwks.dll as well.

일러주는 대로 ".cordll..." 명령을 내려도 마찬가지!

0:000> .cordll -ve -u -l
CLR DLL status: No load attempts

다시 한번 "!pe" 명령을 내려보았는데, 웬일인지 이번에는 좀 더 친절한 메시지를 출력해 주었습니다.

0:000> !pe
CLRDLL: C:\Windows\Microsoft.NET\Framework\v2.0.50727\mscordacwks.dll:2.0.50727.42 f:0
doesn't match desired version 2.0.50727.4200 f:0
SYMSRV:  \\localhost\d$\Symbols\mscordacwks_x86_x86_2.0.50727.4200.dll\4A9EE474590000\mscordacwks_x86_x86_2.0.50727.4200.dll not found
SYMSRV:  http://msdl.microsoft.com/download/symbols/mscordacwks_x86_x86_2.0.50727.4200.dll/4A9EE474590000/mscordacwks_x86_x86_2.0.50727.4200.dll not found
SYMSRV:  The operation timed out
CLRDLL: Unable to find mscordacwks_x86_x86_2.0.50727.4200.dll by mscorwks search
CLRDLL: Unable to find 'mscordacwks_x86_x86_2.0.50727.4200.dll' on the path
SYMSRV:  \\localhost\d$\Symbols\mscorwks.dll\4A9EE474590000\mscorwks.dll not found
SYMSRV:  http://msdl.microsoft.com/download/symbols/mscorwks.dll/4A9EE474590000/mscorwks.dll not found
SYMSRV:  The operation timed out
CLRDLL: Unable to find mscorwks.dll by search
CLRDLL: ERROR: Unable to load DLL mscordacwks_x86_x86_2.0.50727.4200.dll, Win32 error 0n2
Failed to load data access DLL, 0x80004005
Verify that 1) you have a recent build of the debugger (6.2.14 or newer)
            2) the file mscordacwks.dll that matches your version of mscorwks.dll is 
                in the version directory
            3) or, if you are debugging a dump file, verify that the file 
                mscordacwks_<arch>_<arch>_<version>.dll is on your symbol path.
            4) you are debugging on the same architecture as the dump file.
                For example, an IA64 dump file must be debugged on an IA64
                machine.

You can also run the debugger command .cordll to control the debugger's
load of mscordacwks.dll.  .cordll -ve -u -l will do a verbose reload.
If that succeeds, the SOS command should work on retry.

If you are debugging a minidump, you need to make sure that your executable
path is pointing to mscorwks.dll as well.

즉, 문제의 원인이란 것이 덤프를 생성했던 "Windows Server 2008 SP2" 시스템의 mscordacwks.dll을 마이크로소프트 측의 심벌 서버에서도 찾을 수 없었고, 제 시스템(Windows 7)의 mscordacwks.dll과도 다른 버전이라는 것입니다. (근데... 버전 차이가 묘하네요. "2.0.50727.42" / "2.0.50727.4200")

검색을 해보았더니 아래의 글에 해결책이 있습니다.

"Failed to load data access DLL, 0x80004005" ? OR ? What is mscordacwks.dll?
; http://blogs.msdn.com/b/dougste/archive/2009/02/18/failed-to-load-data-access-dll-0x80004005-or-what-is-mscordacwks-dll.aspx

정리해 보면, 그냥 간단하게 고객사 측에 "C:\Windows\Microsoft.NET\Framework\v2.0.50727\mscordacwks.dll" 파일을 요청한 후에, 아래의 메시지에서 보았던 경로에 정확하게 파일명까지 변경해서 넣어주면 됩니다.

SYMSRV:  \\localhost\d$\Symbols\mscordacwks_x86_x86_2.0.50727.4200.dll\4A9EE474590000\mscordacwks_x86_x86_2.0.50727.4200.dll not found




[이 글에 대해서 여러분들과 의견을 공유하고 싶습니다. 틀리거나 미흡한 부분 또는 의문 사항이 있으시면 언제든 댓글 남겨주십시오.]

[연관 글]






[최초 등록일: ]
[최종 수정일: 10/19/2022]

Creative Commons License
이 저작물은 크리에이티브 커먼즈 코리아 저작자표시-비영리-변경금지 2.0 대한민국 라이센스에 따라 이용하실 수 있습니다.
by SeongTae Jeong, mailto:techsharer at outlook.com

비밀번호

댓글 작성자
 



2011-11-24 11시20분
windbg의 mscordacwks DLL 로드 문제
; http://www.sysnet.pe.kr/2/0/1181
정성태

... 181  182  183  184  185  186  187  188  189  190  191  192  193  194  [195]  ...
NoWriterDateCnt.TitleFile(s)
66정성태10/16/200420308.NET Framework: 16. [닷넷 리모팅] 프록시가 죽은 것을 원격 개체가 알 수 있는 방법은?
65정성태10/16/200419266VS.NET IDE: 8. Windows 가상 메모리 사용 해제
64정성태10/3/200422968.NET Framework: 15. ASP.NET에서 .NET COM+ 개체 등록 시 "Local System"이어야 하는 이유.
63정성태10/3/200423069.NET Framework: 14. Response.Cookies.Clear는 기존 설정된 Cookie 헤더를 삭제하는 것이 아닙니다.
62정성태10/3/200422058기타: 7. DB 트랜잭션에서 Lock이 걸릴 수 있는 전형적인 예.
61정성태10/3/200421617.NET Framework: 13. Main 메서드에 붙은 STAThread 의미
60정성태10/3/200420326.NET Framework: 12. IDispatch::GetIDsOfNames 역변환 메서드 작성 힌트 ( DISPID 로 메서드 이름 알아내는 것 )
58정성태10/3/200423415.NET Framework: 11. HttpContext의 간략이해
56정성태10/3/200419906.NET Framework: 10. [.NET 리모팅] 원격개체를 호출한 클라이언트의 연결이 유효한지 판단하는 방법.
55정성태10/3/200420657COM 개체 관련: 11. 내가 생각해 보는 COM의 현재 위치
54정성태8/30/200426319VC++: 10. 내가 생각해 보는 MFC OCX와 ATL DLL에 선택 기준
53정성태11/20/200525679VC++: 9. CFtpFileFind/FtpFileFind가 일부 Unix FTP 서버에서 목록을 제대로 못 가져오는 문제
184정성태11/23/200519341    답변글 VC++: 9.1. FTP 관련 토픽파일 다운로드1
51정성태6/24/200424232VC++: 8. BSTR 메모리 할당 및 해제(MSDN Library 발췌) [1]
50정성태6/16/200417585기타: 6. 1차 데스크톱 컴퓨터 사양
49정성태6/16/200418064기타: 5. 53만 원대 Second PC 마련. ^^
48정성태3/2/200419944.NET Framework: 9. 윈도우즈 발전사를 모아 둔 사이트. [1]
47정성태11/14/200518412VS.NET IDE: 7. 한글 OS에서 Internet Explorer 6.0 with SP1의 UI 언어 바꾸는 방법
45정성태1/26/200417775기타: 4. MCAD 시험
44정성태1/26/200418559VS.NET IDE: 6. 터미널 서비스 포트 변경 ( 서버 및 클라이언트 )
46정성태1/26/200423645    답변글 VS.NET IDE: 6.1. Windows 2003 터미널 서비스 라이센스 서버 없이 접속
114정성태11/14/200515092    답변글 VS.NET IDE: 6.2. [터미널 서버 라이센스] : 활성화 시 오류
43정성태12/23/200318295기타: 3. XP/2003 개인 방화벽 설정파일 다운로드1
40정성태7/23/200321783COM 개체 관련: 10. IE BHO 개체를 개발할 때, 인터넷 익스플로러가 아닌 탐색기에서 활성화 되는 문제 해결 [1]
41김성현7/24/200320579    답변글 COM 개체 관련: 10.1. [답변]: IE BHO 개체를 개발할 때, 인터넷 익스플로러가 아닌 탐색기에서 활성화 되는 문제 해결
42정성태7/29/200318502        답변글 COM 개체 관련: 10.2. feedback 을 받기 위해서 답변 기능을 가능하게 해두었습니다.
... 181  182  183  184  185  186  187  188  189  190  191  192  193  194  [195]  ...