Microsoft MVP성태의 닷넷 이야기
오류 유형: 660. Web Deploy (msdeploy.axd) 실행 시 오류 기록 [링크 복사], [링크+제목 복사]
조회: 20672
글쓴 사람
정성태 (techsharer at outlook.com)
홈페이지
첨부 파일
 

Web Deploy (msdeploy.axd) 실행 시 오류 기록

우선, IIS 웹 서버 측에 아무것도 설치되어 있지 않은 경우 비주얼 스튜디오에서 배포하면 다음과 같은 오류가 발생합니다.

Web deployment task failed. (Could not connect to the remote computer ("192.168.100.5"). On the remote computer, make sure that Web Deploy is installed and that the required process ("Web Management Service") is started.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_DESTINATION_NOT_REACHABLE.)

This error indicates that you cannot connect to the server. Make sure the service URL is correct, firewall and network settings on this computer and on the server computer are configured properly, and the appropriate services have been started on the server.

Error details:
Could not connect to the remote computer ("192.168.100.5"). On the remote computer, make sure that Web Deploy is installed and that the required process ("Web Management Service") is started.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_DESTINATION_NOT_REACHABLE.
Unable to connect to the remote server
No connection could be made because the target machine actively refused it 192.168.100.5:8172

당연히 해당 IIS 서버 측에 "Management Service" 구성 요소를 설치하고,

[Add Roles and Features]
Web Server (IIS)
    - Management Tools
        - Management Service

Web Deployment Tool 도구를 설치해야 합니다.

Configure the Web Deployment Handler
; https://learn.microsoft.com/en-us/iis/publish/using-web-deploy/configure-the-web-deployment-handler

Installing the Web Deployment Tool.
; https://learn.microsoft.com/en-us/iis/publish/using-web-deploy/use-the-web-deployment-tool

Web Deployment Tool
; https://www.iis.net/downloads/microsoft/web-deploy
; https://www.microsoft.com/en-us/download/details.aspx?id=43717

이후 서비스 관리자에서 2개의 서비스가 "Running" 상태인지를 확인합니다.

  • WMSvc - Web Management Service
  • MsDepSvc - Web Deployment Agent Service




그래도 다음과 같은 오류가 발생할 수 있습니다.

Web deployment task failed. (Connected to the remote computer ("192.168.100.5") using the specified process ("Web Management Service"), but could not verify the server’s certificate. If you trust the server, connect again and allow untrusted certificates.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_CERTIFICATE_VALIDATION_FAILED.)

Connected to the remote computer ("192.168.100.5") using the specified process ("Web Management Service"), but could not verify the server’s certificate. If you trust the server, connect again and allow untrusted certificates.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_CERTIFICATE_VALIDATION_FAILED.
The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel.
The remote certificate is invalid according to the validation procedure.

이런 경우엔 차라리 비주얼 스튜디오 측의 배포 대화창에서 "Edit"로 들어가,

iis_dep_error_1.png

UI 상에서 "Validate Connection" 버튼을 눌러 뜨는 오류 창에서 "Save this certificate for future sessions of Visual Studio" 옵션을 체크한 후 "Accept"를 선택하면 인증서를 신뢰합니다.




또는, 403 Forbidden 오류가 발생할 수도 있습니다.

Web deployment task failed. (Could not connect to the remote computer ("192.168.100.5") using the specified process ("Web Management Service") because the server did not respond. Make sure that the process ("Web Management Service") is started on the remote computer.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_COULD_NOT_CONNECT_TO_REMOTESVC.)

Could not connect to the remote computer ("192.168.100.5") using the specified process ("Web Management Service") because the server did not respond. Make sure that the process ("Web Management Service") is started on the remote computer.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_COULD_NOT_CONNECT_TO_REMOTESVC.
The remote server returned an error: (403) Forbidden.

이럴 때는, 서비스 관리자에서 "WMSVC(Web Management Service)"를 중지 시킨 후, IIS 관리자에서 (컴퓨터 이름이 출력되는) 서버 노드의 "Management Service"로 들어가 "Enable remote connections"를 활성화하고,

iis_dep_error_2.png

다시 WMSVC를 시작하면 됩니다.




그래도 404 Not Found 오류가 발생한다면?

Web deployment task failed. (Could not connect to the remote computer ("192.168.100.5"). On the remote computer, make sure that Web Deploy is installed and that the required process ("Web Management Service") is started.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_DESTINATION_NOT_REACHABLE.)
The requested resource does not exist, or the requested URL is incorrect.

Could not connect to the remote computer ("192.168.100.5"). On the remote computer, make sure that Web Deploy is installed and that the required process ("Web Management Service") is started.  Learn more at: https://go.microsoft.com/fwlink/?LinkId=221672#ERROR_DESTINATION_NOT_REACHABLE.
The remote server returned an error: (404) Not Found.

WMSVC의 로그가 남는 디렉터리에(기본값으로 %SystemDrive%\Inetpub\logs\WMSvc) 가보면 보다 구체적인 substatus 코드를 알 수 있습니다.

#Software: Microsoft Internet Information Services 10.0
#Version: 1.0
#Date: 2020-09-29 05:47:43
#Fields: date time s-ip cs-method cs-uri-stem cs-uri-query s-port cs-username c-ip cs(User-Agent) cs(Referer) sc-status sc-substatus sc-win32-status time-taken
2020-09-29 05:47:43 192.168.100.5 HEAD /msdeploy.axd site=Blazor2 8172 - 192.168.0.19 - - 404 7 0 1062
2020-09-29 05:47:44 192.168.100.5 HEAD /msdeploy.axd site=Blazor2 8172 - 192.168.0.19 - - 404 7 0 0
2020-09-29 05:47:44 192.168.100.5 HEAD /msdeploy.axd site=Blazor2 8172 - 192.168.0.19 - - 404 7 0 15

위에서는 "404.7"로 "File Extension Denied"를 의미하는데요, 시스템에 "AXD-ISAPI-4.0_32bit" / "AXD-ISAPI-4.0_64bit"라는 이름의 핸들러(*.axd) 매핑이 없기 때문입니다.

직접 구성해도 되지만, 그냥 이런 경우에는 "Web Deploy" 도구를 제거하고 다시 설치할 때 다음과 같이 "IIS Deployment Handler"와 "Remote Agent Service"를 명시적으로 체크해 진행하면 됩니다.

iis_dep_error_3.png




[이 글에 대해서 여러분들과 의견을 공유하고 싶습니다. 틀리거나 미흡한 부분 또는 의문 사항이 있으시면 언제든 댓글 남겨주십시오.]







[최초 등록일: ]
[최종 수정일: 3/9/2024]

Creative Commons License
이 저작물은 크리에이티브 커먼즈 코리아 저작자표시-비영리-변경금지 2.0 대한민국 라이센스에 따라 이용하실 수 있습니다.
by SeongTae Jeong, mailto:techsharer at outlook.com

비밀번호

댓글 작성자
 



2021-06-23 03시43분
Locked Files When Publishing .NET Core Apps to IIS with WebDeploy
; https://weblog.west-wind.com/posts/2021/Jun/20/Locked-Files-When-Publishing-NET-Core-Apps-to-IIS-with-WebDeploy

app_offline.htm
<EnableMSDeployAppOffline>true</EnableMSDeployAppOffline>
정성태

... 16  17  [18]  19  20  21  22  23  24  25  26  27  28  29  30  ...
NoWriterDateCnt.TitleFile(s)
13180정성태12/2/20224940.NET Framework: 2074. C# - 스택 메모리에 대한 여유 공간 확인하는 방법파일 다운로드1
13179정성태12/2/20224360Windows: 216. Windows 11 - 22H2 업데이트 이후 Terminal 대신 cmd 창이 뜨는 경우
13178정성태12/1/20224860Windows: 215. Win32 API 금지된 함수 - IsBadXxxPtr 유의 함수들이 안전하지 않은 이유파일 다운로드1
13177정성태11/30/20225591오류 유형: 829. uwsgi 설치 시 fatal error: Python.h: No such file or directory
13176정성태11/29/20224516오류 유형: 828. gunicorn - ModuleNotFoundError: No module named 'flask'
13175정성태11/29/20226141오류 유형: 827. Python - ImportError: cannot import name 'html5lib' from 'pip._vendor'
13174정성태11/28/20224706.NET Framework: 2073. C# - VMMap처럼 스택 메모리의 reserve/guard/commit 상태 출력파일 다운로드1
13173정성태11/27/20225396.NET Framework: 2072. 닷넷 응용 프로그램의 스레드 스택 크기 변경
13172정성태11/25/20225205.NET Framework: 2071. 닷넷에서 ESP/RSP 레지스터 값을 구하는 방법파일 다운로드1
13171정성태11/25/20224818Windows: 214. 윈도우 - 스레드 스택의 "red zone"
13170정성태11/24/20225127Windows: 213. 윈도우 - 싱글 스레드는 컨텍스트 스위칭이 없을까요?
13169정성태11/23/20225710Windows: 212. 윈도우의 Protected Process (Light) 보안 [1]파일 다운로드2
13168정성태11/22/20224995제니퍼 .NET: 31. 제니퍼 닷넷 적용 사례 (9) - DB 서비스에 부하가 걸렸다?!
13167정성태11/21/20225034.NET Framework: 2070. .NET 7 - Console.ReadKey와 리눅스의 터미널 타입
13166정성태11/20/20224759개발 환경 구성: 651. Windows 사용자 경험으로 WSL 환경에 dotnet 런타임/SDK 설치 방법
13165정성태11/18/20224664개발 환경 구성: 650. Azure - "scm" 프로세스와 엮인 서비스 모음
13164정성태11/18/20225564개발 환경 구성: 649. Azure - 비주얼 스튜디오를 이용한 AppService 원격 디버그 방법
13163정성태11/17/20225502개발 환경 구성: 648. 비주얼 스튜디오에서 안드로이드 기기 인식하는 방법
13162정성태11/15/20226585.NET Framework: 2069. .NET 7 - AOT(ahead-of-time) 컴파일
13161정성태11/14/20225801.NET Framework: 2068. C# - PublishSingleFile로 배포한 이미지의 역어셈블 가능 여부 (난독화 필요성) [4]
13160정성태11/11/20225752.NET Framework: 2067. C# - PublishSingleFile 적용 시 native/managed 모듈 통합 옵션
13159정성태11/10/20228963.NET Framework: 2066. C# - PublishSingleFile과 관련된 옵션 [3]
13158정성태11/9/20225230오류 유형: 826. Workload definition 'wasm-tools' in manifest 'microsoft.net.workload.mono.toolchain' [...] conflicts with manifest 'microsoft.net.workload.mono.toolchain.net7'
13157정성태11/8/20225893.NET Framework: 2065. C# - Mutex의 비동기 버전파일 다운로드1
13156정성태11/7/20226800.NET Framework: 2064. C# - Mutex와 Semaphore/SemaphoreSlim 차이점파일 다운로드1
13155정성태11/4/20226300디버깅 기술: 183. TCP 동시 접속 (연결이 아닌) 시도를 1개로 제한한 서버
... 16  17  [18]  19  20  21  22  23  24  25  26  27  28  29  30  ...