Microsoft MVP성태의 닷넷 이야기
글쓴 사람
정성태 (techsharer at outlook.com)
홈페이지
첨부 파일
 

OpCodes.Box와 관련해 IL 형식으로 직접 코딩 시 유의할 점

C# 코드에서 object에 값 형식을 전달하는 코드를 보면,

using System;

class Program
{
    static void Main(string[] args)
    {
        System.Threading.CancellationToken token = new System.Threading.CancellationToken();
        LogOutput(token); // boxing
        Console.WriteLine("End-of-Test4");
    }

    static void LogOutput(object instance)
    {
        Console.WriteLine(instance ?? "null");
    }
}
/* 출력 결과
System.Threading.CancellationToken
End-of-Test4
*/

token 인스턴스가 자연스럽게 object에 대입되는 것처럼 보이지만, 이 과정을 IL 코드로 보면 box 코드가 관여합니다.

.method private hidebysig static void  Main(string[] args) cil managed
{
    .entrypoint
    .maxstack  1
    .locals init ([0] valuetype [mscorlib]System.Threading.CancellationToken token)
    IL_0000:  nop
    IL_0001:  ldloca.s   token
    IL_0003:  initobj    [mscorlib]System.Threading.CancellationToken
    IL_0009:  ldloc.0
    IL_000a:  box        [mscorlib]System.Threading.CancellationToken
    IL_000f:  call       void Program::LogOutput(object)
    IL_0014:  nop
    IL_0015:  ldstr      "End-of-Test4"
    IL_001a:  call       void [mscorlib]System.Console::WriteLine(string)
    IL_001f:  nop
    IL_0020:  ret
} // end of method Program::Main

.method private hidebysig static void  LogOutput(object 'instance') cil managed
{
    // ...[생략]...
}

위의 경우 box 연산자와 함께 "[mscorlib]System.Threading.CancellationToken" 문자열 형식을 전달하는데, 이것은 IL 언어에서 문법적으로 지원하기 때문에 가능한 것이고 만약 바이트를 직접 출력하는 경우라면 다음과 같이 코딩을 해야 합니다.

0x8c, 0x01000011

// box IL 코드 == 0x8c
//
// 0x01000011 == System.Threading.CancellationToken 타입에 대한 메타데이터의 토큰값




그런데, 여기서 실수를 해 box 연산자를 누락한다면 어떻게 될까요? 실제로 위의 IL 소스 코드에서 box 라인만 주석 처리해,

.method private hidebysig static void  Main(string[] args) cil managed
{
    // ...[생략]...
    IL_0009:  ldloc.0
    // IL_000a:  box        [mscorlib]System.Threading.CancellationToken
    IL_000f:  call       void Program::LogOutput(object)
    IL_0014:  nop
    IL_0015:  ldstr      "End-of-Test4"
    IL_001a:  call       void [mscorlib]System.Console::WriteLine(string)
    // ...[생략]...
}

ilasm.exe로 exe를 생성/실행하면 화면에는 "(null)"이라는 출력이 나옵니다. 그나마 동작을 하는 듯하지만, 이것은 사실 "예측할 수 없다"는 것이 맞습니다. 이번엔 의도와는 다르게 출력이 되었어도 운이 좋게 프로그램이 종료하지는 않았는데요, 이 코드에서 다음과 같이 직접 정의한 구조체로 바꿔보면,

using System;

class Program
{
    static void Main(string[] args)
    {
        MyStruct token = new MyStruct();
        LogOutput(token);
        Console.WriteLine("End-of-Test4");
    }

    static void LogOutput(object instance)
    {
        Console.WriteLine(instance ?? "null");
    }
}

public struct MyStruct
{
    public int Age;
    public string Name;
}

이번에는 프로그램이 비정상 종료하면서 이벤트 로그에 다음과 같은 유형의 오류들이 쌓이는 것을 볼 수 있습니다.

Log Name:      Application
Source:        .NET Runtime
Date:          2018-09-23 오전 11:22:53
Event ID:      1023
Task Category: None
Level:         Error
Keywords:      Classic
User:          N/A
Computer:      TESTPC
Description:
Application: console.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an internal error in the .NET Runtime at IP 00007FF83A503E30 (00007FF83A500000) with exit code 80131506.

Log Name:      Application
Source:        Application Error
Date:          2018-09-23 오전 11:22:53
Event ID:      1000
Task Category: (100)
Level:         Error
Keywords:      Classic
User:          N/A
Computer:      TESTPC
Description:
Faulting application name: console.exe, version: 0.0.0.0, time stamp: 0x5f8660ca
Faulting module name: clr.dll, version: 4.8.4250.0, time stamp: 0x5f2a059c
Exception code: 0xc0000005
Fault offset: 0x0000000000003e30
Faulting process id: 0x6060
Faulting application start time: 0x01d6a1d0ebe4a979
Faulting application path: C:\temp\bin\Debug\console.exe
Faulting module path: C:\Windows\Microsoft.NET\Framework64\v4.0.30319\clr.dll
Report Id: a4412515-d89d-462a-9df6-1f428b6ad155
Faulting package full name: 
Faulting package-relative application ID: 

Log Name:      Application
Source:        Windows Error Reporting
Date:          2018-09-23 오전 11:22:55
Event ID:      1001
Task Category: None
Level:         Information
Keywords:      Classic
User:          N/A
Computer:      TESTPC
Description:
Fault bucket 1335692000105475064, type 4
Event Name: APPCRASH
Response: Not available
Cab Id: 0

Problem signature:
P1: console.exe
P2: 0.0.0.0
P3: 5f8660ca
P4: clr.dll
P5: 4.8.4250.0
P6: 5f2a059c
P7: c0000005
P8: 0000000000003e30
P9: 
P10: 

Attached files:
\\?\C:\ProgramData\Microsoft\Windows\WER\Temp\WER4D67.tmp.WERInternalMetadata.xml

These files may be available here:
\\?\C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_console.exe_cc693ced9f02ff1fad4971022e1a719ec05145_c6eba193_bcbd42d7-ebe2-4c60-9a33-8dbc2d5cc5ee

Analysis symbol: 
Rechecking for solution: 0
Report Id: a4412515-d89d-462a-9df6-1f428b6ad155
Report Status: 268435456
Hashed bucket: eedc651829064f20028954cc1b9e2bf8
Cab Guid: 0

재현을 하진 못했지만, 어떤 때는 해당 코드를 가진 메서드의 실행 시 "System.Security.VerificationException" 예외가 발생하는 경우도 있습니다.

따라서, 값 형식을 object로 넘길 때는 box 연산을 반드시 잊지 않고 사용해야 합니다.




[이 글에 대해서 여러분들과 의견을 공유하고 싶습니다. 틀리거나 미흡한 부분 또는 의문 사항이 있으시면 언제든 댓글 남겨주십시오.]







[최초 등록일: ]
[최종 수정일: 10/14/2020]

Creative Commons License
이 저작물은 크리에이티브 커먼즈 코리아 저작자표시-비영리-변경금지 2.0 대한민국 라이센스에 따라 이용하실 수 있습니다.
by SeongTae Jeong, mailto:techsharer at outlook.com

비밀번호

댓글 작성자
 




... 121  122  123  124  125  126  127  128  129  130  131  132  [133]  134  135  ...
NoWriterDateCnt.TitleFile(s)
1764정성태9/30/201423737오류 유형: 243. 파일 삭제가 안 되는 경우 - The action can't be comleted because the file is open in System
1763정성태9/30/201425261.NET Framework: 468. PDB 파일을 연동해 소스 코드 라인 정보를 알아내는 방법파일 다운로드1
1762정성태9/30/201426093.NET Framework: 467. 닷넷에서 EIP/RIP 레지스터 값을 구하는 방법 [1]파일 다운로드1
1761정성태9/29/201423246.NET Framework: 466. 윈도우 운영체제의 보안 그룹 이름 및 설명 문자열을 바꾸는 방법파일 다운로드1
1760정성태9/28/201421242.NET Framework: 465. ICorProfilerInfo::GetILToNativeMapping 메서드가 0x80131358을 반환하는 경우
1759정성태9/27/201432531개발 환경 구성: 240. Visual C++ / x64 환경에서 inline-assembly를 매크로 어셈블리로 대체하는 방법파일 다운로드1
1758정성태9/23/201439145개발 환경 구성: 239. 원격 데스크톱 접속(RDP)을 기존의 콘솔 모드처럼 사용하는 방법 [1]
1757정성태9/23/201419764오류 유형: 242. Lync로 모임 참여 시 소리만 들리지 않는 경우 - 두 번째 이야기
1756정성태9/23/201428900기타: 48. NVidia 제품의 과다한 디스크 사용 [2]
1755정성태9/22/201435725오류 유형: 241. Unity Web Player를 설치해도 여전히 설치하라는 화면이 나오는 경우 [4]
1754정성태9/22/201426069VC++: 80. 내 컴퓨터에서 C++ AMP 코드가 실행이 될까요? [1]
1753정성태9/22/201421859오류 유형: 240. Lync로 세미나 참여 시 소리만 들리지 않는 경우 [1]
1752정성태9/21/201441986Windows: 100. 윈도우 8 - RDP 연결을 이용해 VNC처럼 사용자 로그온 화면을 공유하는 방법 [5]
1751정성태9/20/201440083.NET Framework: 464. 프로세스 간 통신 시 소켓 필요 없이 간단하게 Pipe를 열어 통신하는 방법 [1]파일 다운로드1
1750정성태9/20/201425332.NET Framework: 463. PInvoke 호출을 이용한 비동기 파일 작업파일 다운로드1
1749정성태9/20/201425073.NET Framework: 462. 커널 객체를 위한 null DACL 생성 방법파일 다운로드1
1748정성태9/19/201426609개발 환경 구성: 238. [Synergy] 여러 컴퓨터에서 키보드, 마우스 공유
1747정성태9/19/201429923오류 유형: 239. psexec 실행 오류 - The system cannot find the file specified.
1746정성태9/18/201426885.NET Framework: 461. .NET EXE 파일을 닷넷 프레임워크 버전에 상관없이 실행할 수 있을까요? - 두 번째 이야기 [6]파일 다운로드1
1745정성태9/17/201424411개발 환경 구성: 237. 리눅스 Integration Services 버전 업그레이드 하는 방법 [1]
1744정성태9/17/201432303.NET Framework: 460. GetTickCount / GetTickCount64와 0x7FFE0000 주솟값 [4]파일 다운로드1
1743정성태9/16/201422086오류 유형: 238. 설치 오류 - Failed to get size of pseudo bundle
1742정성태8/27/201428433개발 환경 구성: 236. Hyper-V에 설치한 리눅스 VM의 VHD 크기 늘리는 방법 [2]
1741정성태8/26/201422539.NET Framework: 459. GetModuleHandleEx로 알아보는 .NET 메서드의 DLL 모듈 관계파일 다운로드1
1740정성태8/25/201433945.NET Framework: 458. 닷넷 GC가 순환 참조를 해제할 수 있을까요? [2]파일 다운로드1
1739정성태8/24/201427763.NET Framework: 457. 교착상태(Dead-lock) 해결 방법 - Lock Leveling [2]파일 다운로드1
... 121  122  123  124  125  126  127  128  129  130  131  132  [133]  134  135  ...