WinDbg - 덤프 분석 중인 닷넷 어셈블리가 Debug 빌드인지, Release 빌드인지 알아내는 방법

혹시, WinDbg에서도 분석 중인 모듈의 빌드 상태를 알아낼 수 있을까요?

해당 어셈블리가 Debug 빌드인지, Release 빌드인지 알아내는 방법
; https://www.sysnet.pe.kr/2/0/1227

일단, lm 명령어로는 딱히 나오는 것이 없습니다.

0:000> lmDvmConsoleApp1
Browse full module list
start             end                 module name
000001c2`6e4e0000 000001c2`6e4e8000   ConsoleApp1   (deferred)             
    Image path: c:\temp\builds\ConsoleApp1\AnyCPU\Debug\ConsoleApp1.dll
    Image name: ConsoleApp1.dll
    Browse all global symbols  functions  data  Symbol Reload
    Using CLR debugging support for all symbols
    Has CLR image header, track-debug-data flag not set
    Image was built with /Brepro flag.
    Timestamp:        A845CF62 (This is a reproducible build file hash, not a timestamp)
    CheckSum:         00000000
    ImageSize:        00008000
    Mapping Form:     Loaded
    File version:     1.0.0.0
    Product version:  1.0.0.0
    File flags:       0 (Mask 3F)
    File OS:          4 Unknown Win32
    File type:        1.0 App
    File date:        00000000.00000000
    Translations:     0000.04b0
    Information from resource tables:
        CompanyName:      ConsoleApp1
        ProductName:      ConsoleApp1
        InternalName:     ConsoleApp1.dll
        OriginalFilename: ConsoleApp1.dll
        ProductVersion:   1.0.0
        FileVersion:      1.0.0.0
        FileDescription:  ConsoleApp1
        LegalCopyright:    

중간에 "track-debug-data flag not set"이라는 문구가 있는데, Debug/Release 모두 동일한 문자열이 나왔습니다. 이제 남은 것은 sos 확장 명령어인데요, 그나마 쓸모 있는 정보가 DumpModule의 TransientFlags로 나오는 듯합니다.

// Debug 빌드인 경우

0:000> !DumpModule /d 00007ffe2c7b7770
Name: c:\temp\builds\ConsoleApp1\AnyCPU\Debug\ConsoleApp1.dll
Attributes:              PEFile 
TransientFlags:          00209019 IS_EDIT_AND_CONTINUE
Assembly:                000001c26cb3d3c0
BaseAddress:             000001C26E4E0000
LoaderHeap:              0000000000000000
TypeDefToMethodTableMap: 00007FFE2C7A2240
TypeRefToMethodTableMap: 00007FFE2C7A2270
MethodDefToDescMap:      00007FFE2C7A2358
FieldDefToDescMap:       00007FFE2C7A23B0
MemberRefToDescMap:      0000000000000000
FileReferencesMap:       00007FFE2C7A23D8
AssemblyReferencesMap:   00007FFE2C7A23E0
MetaData start address:  000001C26E4E21BC (2664 bytes)

// Release 빌드인 경우

0:000> !DumpModule /d 00007ffe2c7f7778
Name: c:\temp\builds\ConsoleApp1\AnyCPU\Release\ConsoleApp1.dll
Attributes:              PEFile 
TransientFlags:          00208811 
Assembly:                00000227fc48bca0
BaseAddress:             00000227FDF50000
LoaderHeap:              0000000000000000
TypeDefToMethodTableMap: 00007FFE2C7E2240
TypeRefToMethodTableMap: 00007FFE2C7E2270
MethodDefToDescMap:      00007FFE2C7E2348
FieldDefToDescMap:       00007FFE2C7E23A0
MemberRefToDescMap:      0000000000000000
FileReferencesMap:       00007FFE2C7E23C8
AssemblyReferencesMap:   00007FFE2C7E23D0
MetaData start address:  00000227FDF5219C (2572 bytes)

위의 경우, "IS_EDIT_AND_CONTINUE"는 Visual Studio에서 "Edit and Continue" 옵션을 켠 경우에 나타난 것입니다. 그게 꺼져 있다면 출력은 이런 식으로 바뀝니다. (각자의 빌드 옵션에 따라 다릅니다.)

// ("Enable Hot Reload" 옵션을 끈) Debug 빌드인 경우

0:007> !DumpModule /d 00007ffe2c7d7770
Name: c:\temp\builds\ConsoleApp1\AnyCPU\Debug\ConsoleApp1.dll
Attributes:              PEFile 
TransientFlags:          00209011 
Assembly:                000001b13553ac80
BaseAddress:             000001B137040000
LoaderHeap:              0000000000000000
TypeDefToMethodTableMap: 00007FFE2C7C2240
TypeRefToMethodTableMap: 00007FFE2C7C2270
MethodDefToDescMap:      00007FFE2C7C2370
FieldDefToDescMap:       00007FFE2C7C23C8
MemberRefToDescMap:      0000000000000000
FileReferencesMap:       00007FFE2C7C23F0
AssemblyReferencesMap:   00007FFE2C7C23F8
MetaData start address:  000001B1370421D4 (2792 bytes)

그렇다면, 관련해서 TransientFlags 내부에 디버그 빌드에 준하는 정보가 남아 있지 않을까요? ^^ 이를 알아 보기 위해 sos 소스 코드에서 다음과 같은 enum 정보를 찾았는데요,

src/SOS/Strike/strike.cpp
; https://github.com/dotnet/diagnostics/blob/ea6796b6d0556f8ab3c01d0c0d8f234fdfdf1d73/src/SOS/Strike/strike.cpp#L3918

enum {
    // These are the values set in m_dwTransientFlags.
    // Note that none of these flags survive a prejit save/restore.

    MODULE_IS_TENURED           = 0x00000001,   // Set once we know for sure the Module will not be freed until the appdomain itself exits
    // unused                   = 0x00000002,
    CLASSES_FREED               = 0x00000004,
    IS_EDIT_AND_CONTINUE        = 0x00000008,   // is EnC Enabled for this module

    IS_PROFILER_NOTIFIED        = 0x00000010,
    IS_ETW_NOTIFIED             = 0x00000020,

    //
    // Note: the order of these must match the order defined in
    // cordbpriv.h for DebuggerAssemblyControlFlags. The three
    // values below should match the values defined in
    // DebuggerAssemblyControlFlags when shifted right
    // DEBUGGER_INFO_SHIFT bits.
    //
    DEBUGGER_USER_OVERRIDE_PRIV = 0x00000400,
    DEBUGGER_ALLOW_JIT_OPTS_PRIV= 0x00000800,
    DEBUGGER_TRACK_JIT_INFO_PRIV= 0x00001000,
    DEBUGGER_ENC_ENABLED_PRIV   = 0x00002000,   // this is what was attempted to be set.  IS_EDIT_AND_CONTINUE is actual result.
    DEBUGGER_PDBS_COPIED        = 0x00004000,
    DEBUGGER_IGNORE_PDBS        = 0x00008000,
    DEBUGGER_INFO_MASK_PRIV     = 0x0000Fc00,
    DEBUGGER_INFO_SHIFT_PRIV    = 10,

    // Used to indicate that this module has had it's IJW fixups properly installed.
    IS_IJW_FIXED_UP             = 0x00080000,
    IS_BEING_UNLOADED           = 0x00100000,

    // Used to indicate that the module is loaded sufficiently for generic candidate instantiations to work
    MODULE_READY_FOR_TYPELOAD  = 0x00200000,

    // Used during NGen only
    TYPESPECS_TRIAGED           = 0x40000000,
    MODULE_SAVED                = 0x80000000,
};

이에 비춰서 TransientFlags 값을 분석하면 각각 다음과 같이 펼쳐집니다.

// Debug 빌드인 경우

TransientFlags:          00209019
    - MODULE_READY_FOR_TYPELOAD
    - DEBUGGER_IGNORE_PDBS
    - DEBUGGER_TRACK_JIT_INFO_PRIV
    - IS_PROFILER_NOTIFIED
    - IS_EDIT_AND_CONTINUE
    - MODULE_IS_TENURED

// Release 빌드인 경우

TransientFlags:          00208811 
    - MODULE_READY_FOR_TYPELOAD
    - DEBUGGER_IGNORE_PDBS
    - DEBUGGER_ALLOW_JIT_OPTS_PRIV
    - IS_PROFILER_NOTIFIED
    - MODULE_IS_TENURED

// ("Enable Hot Reload" 옵션을 끈) Debug 빌드인 경우

TransientFlags:          00209011 
    - MODULE_READY_FOR_TYPELOAD
    - DEBUGGER_IGNORE_PDBS
    - DEBUGGER_TRACK_JIT_INFO_PRIV
    - IS_PROFILER_NOTIFIED
    - MODULE_IS_TENURED

확신할 수는 없지만, 그냥 저 결과만 보면 DEBUGGER_TRACK_JIT_INFO_PRIV 옵션 유무로 Debug 빌드를 느슨하게 판정할 수는 있을 듯합니다.

참고로, 위의 방법 이외에도 그냥 대상 .NET Assembly를 파일로 덤프시킨 다음,

windbg - 풀 덤프 파일로부터 .NET DLL을 추출/저장하는 방법
; https://www.sysnet.pe.kr/2/0/10943

거기서 Debuggable 특성의 값을 확인하는 것도 고려할 수 있을 것입니다.




유의해야 할 점은, Debug 빌드는 다양한 옵션의 조합이기 때문에 어떤 특정 옵션만을 가지고 Debug 빌드라고 단정할 수는 없습니다. "해당 어셈블리가 Debug 빌드인지, Release 빌드인지 알아내는 방법" 글에서도, DisableOptimizations, EnableEditAndContinue, Default 옵션이 Debuggable 특성에 있는 정도로 판정하는 수준에 불과합니다.




[이 글에 대해서 여러분들과 의견을 공유하고 싶습니다. 틀리거나 미흡한 부분 또는 의문 사항이 있으시면 언제든 댓글 남겨주십시오.]







[최초 등록일: ]
[최종 수정일: 11/10/2025]

Creative Commons License
이 저작물은 크리에이티브 커먼즈 코리아 저작자표시-비영리-변경금지 2.0 대한민국 라이센스에 따라 이용하실 수 있습니다.
by SeongTae Jeong, mailto:techsharer at outlook.com

비밀번호

댓글 작성자
 




... 91  92  93  94  [95]  96  97  98  99  100  101  102  103  104  105  ...
NoWriterDateCnt.TitleFile(s)
11678정성태8/29/201825742오류 유형: 483. 닷넷 - System.InvalidProgramException [1]
11677정성태8/29/201823165오류 유형: 482. TFS - Could not find a part of the path '...\packages\Microsoft.AspNet.WebApi.5.2.5\.signature.p7s'.
11676정성태8/29/201834023.NET Framework: 791. C# - ElasticSearch를 위한 Client 라이브러리 제작 [1]파일 다운로드1
11675정성태8/29/201824936오류 유형: 481. The located assembly's manifest definition does not match the assembly reference.
11674정성태8/29/201824668Phone: 12. Xamarin - 기존 리모컨 기능을 핸드폰의 적외선 송신으로 구현파일 다운로드1
11673정성태8/28/201824196오류 유형: 480. Fritzing 실행 시 Ordinal Not Found 오류
11672정성태8/28/201823107오류 유형: 479. 윈도우 - 시스템 설정에서 도메인 참가를 위한 "Change" 버튼이 비활성화된 경우
11671정성태8/28/201829497사물인터넷: 39. 아두이노에서 적외선 송신기 기본 사용법파일 다운로드1
11670정성태8/28/201829547사물인터넷: 38. 아두이노에서 적외선 수신기 기본 사용법 [1]파일 다운로드1
11669정성태8/24/201827539개발 환경 구성: 394. 윈도우 환경에서 elasticsearch의 한글 블로그 검색 인덱스 구성
11668정성태8/24/201838881오류 유형: 478. 윈도우 업데이트(KB4458842) 이후 SQL Server 서비스 시작 오류
11667정성태8/24/201822840오류 유형: 477. "Use Unicode UTF-8 for worldwide language support" 옵션 설정 시 SQL Server 2016 설치 오류 [1]
11666정성태8/22/201823561사물인터넷: 37. 아두이노 - 코딩으로 대신하는 오실레이터 회로의 소리 출력파일 다운로드1
11665정성태8/22/201828247사물인터넷: 36. 오실레이터 회로 동작을 아두이노의 코딩으로 구현하는 방법파일 다운로드1
11664정성태8/22/201827531개발 환경 구성: 393. 윈도우 환경에서 elasticsearch의 한글 형태소 분석기 설치 [1]
11663정성태8/22/201831002개발 환경 구성: 392. 윈도우 환경에서 curl.exe를 이용한 elasticsearch 6.x 기본 사용법
11662정성태8/21/201821540사물인터넷: 35. 병렬 회로에서의 커패시터파일 다운로드1
11661정성태8/21/201824801사물인터넷: 34. 트랜지스터 동작 - 컬렉터-이미터 간의 저항 측정파일 다운로드1
11660정성태8/19/201824742사물인터넷: 33. 세라믹 커패시터의 동작 방식파일 다운로드1
11659정성태8/19/201825160사물인터넷: 32. 9V 전압에서 테스트하는 PN2222A 트랜지스터파일 다운로드1
11658정성태8/18/201828661사물인터넷: 31. 커패시터와 RC 회로파일 다운로드3
11657정성태8/18/201826806사물인터넷: 30. 릴레이(Relay) 제어파일 다운로드3
11656정성태8/16/201820891사물인터넷: 29. 트랜지스터와 병렬로 연결한 LED파일 다운로드1
11655정성태8/16/201823750사물인터넷: 28. 저항과 병렬로 연결한 LED파일 다운로드1
11654정성태8/15/201825207사물인터넷: 27. 병렬 회로의 저항, 전압 및 전류파일 다운로드1
11653정성태8/14/201826166사물인터넷: 26. 입력 전압에 따른 LED의 전압/저항 변화 [1]파일 다운로드1
... 91  92  93  94  [95]  96  97  98  99  100  101  102  103  104  105  ...